- #PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS CODE#
- #PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS PC#
- #PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS PROFESSIONAL#
For example, fire department connections, fire water service relays and backflow devices should be clearly indicated. All sprinkler filing should include a diagrammatic site plan identifying the location of the work within the building and if exterior work or water service is affected then indicating the location of that work. A drawing index is recommended to clearly identify all the unique systems that may be involved in the proposed work. The applicable Building Codes and notes should be stated on the drawings. The title page should clearly define the project location and vicinity by graphical means.
![proprietary notes for fire sprinkler system design drawings proprietary notes for fire sprinkler system design drawings](https://fiverr-res.cloudinary.com/images/t_main1,q_auto,f_auto,q_auto,f_auto/gigs/146733277/original/54d9ce575fbabd2055caa6ffedfc8373db8e48c4/do-fire-protection-sprinkler-system-design-drafting.jpg)
Drawings necessary to convey essential information such as schedules, riser diagrams, floor layout, mounting details, seismic details, and control diagrams.
#PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS CODE#
Details essential for a complete submission of drawings include (Refer to the NYC Building Code section BC 107.9:Ĭonstruction Documents. The sprinkler drawings represent work that is closely coordinated with many other disciplines such as architectural, structural, electrical, and mechanical, to ensure coordination with other disciplines. Complete Submission of Sprinkler Work Drawings In many cases, the project may involve the documentation of existing sprinkler systems and should clearly identify new versus existing systems. (Refer to the NYC Building Code section BC 107.9.Īlthough the Department does not mandate the organization and style of construction documents, the guidelines outlined in this chapter should provide a consistent approach for preparation of construction documents that will facilitate the plan review process. Based upon the complexity and scale of the project, the information provided on the sprinkler drawings should show a clear description of the work required for the project.
![proprietary notes for fire sprinkler system design drawings proprietary notes for fire sprinkler system design drawings](https://www.tweed.nsw.gov.au/files/assets/public/images/development-and-business/land-use-planning-controls/engineering-design.jpg)
In particular changes to the building layout, occupancy and the hazard of the building contents will impact the design of the sprinkler systems design. Guidelines for Submission of Sprinkler Project PlansĪ pre-design review should cover all existing sprinkler systems and components affected by the proposed scope of work to verify code-compliant repair work, or modifications to the sprinkler systems within the building. You may also need to comply with other City agency requirements, for example: Fire Department (FDNY), Departments of Environmental Protection (DEP), Transportation (DOT), Department of Health and Mental Hygiene, to name a few. List of all required Special and Progress Inspections on construction documentsīuildings Bulletin 2009-006 – This document is a reference guide to the automatic sprinkler system requirements of Chapter 9 of the Building Code.
#PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS PC#
* Note: While the following is a list of key zoning, Code and other regulations that may be relevant in the project’s design, it does not cover all applicable regulations.* Applicable Codes and Reference Standards Project ElementĬonstruction Document Requirements, including a complete description of proposed scope of work on the plans.Ģ014 BC Chapter 9, NFPA 13, 13R, & 13D, and NFPA 14, as modified by BC Appendix QĢ014 BC Chapter 9, NFPA 13 & 14 as Modified by BC Appendix QĢ014 BC Chapter 9, NFPA 20, NFPA 13 and NFPA 14, as modified by BC Appendix QĢ014 BC Chapter 9, PC Chapter 6, NFPA 22, NFPA 13, 13R, and 13D as modified by BC Appendix QĢ014 BC ChapAC §27-318 through §27-353.3, or 1938 BC Article 11Ģ014 BC 1604, BC Appendix Q, PC 308 and NFPA 13 Chapter 9.3.7
![proprietary notes for fire sprinkler system design drawings proprietary notes for fire sprinkler system design drawings](http://engineeredfiresystems.com/wp-content/uploads/2016/04/Plan-Background-8.jpg)
Per the current 2014 Administrative Code, section 28-101.4.3, additions, alterations or modifications to sprinkler systems shall conform to what’s required for new portions without requiring the remaining existing system to comply with all of the current code requirements.
![proprietary notes for fire sprinkler system design drawings proprietary notes for fire sprinkler system design drawings](https://i.pinimg.com/236x/21/ca/2a/21ca2aa7828ac05d6b5f738418c88348--crossword-puzzle.jpg)
#PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS PROFESSIONAL#
Design Professional Requirements: Sprinkler Applicability of Codeįor existing buildings, sprinkler work should comply with the 2014 Administrative Code, section 28-101.4.3 and the remainder of the Construction Codes, but in particular Building Code (BC) Chapter 9.